Can You Still Install R-410A in 2027? EPA Refrigerant Deadlines for HVAC Contractors, Plus Equipment Price Changes

By StartBusinessByStatePublisher: Robert SmithResearch process

Original research · EPA, Federal Register and BLS Producer Price Index data, checked November 17, 2026 · By StartBusinessByState · Published November 17, 2026

Yes, mostly.Home and light commercial R-410A systems made or imported before Jan. 1, 2025 can still be installed in 2027, with no deadline. R-410A VRF systems must be installed by Jan. 1, 2027.

Short answer: the EPA dropped its January 1, 2026 deadline for installing older R-410A home systems. A final rule published May 26, 2026 lets contractors install leftover stock made or imported before 2025 until it runs out. New R-410A equipment can’t be made or imported. Variable refrigerant flow (VRF) systems still face a January 1, 2027 install deadline. Meanwhile, producer prices for AC and heating equipment are up 9.7% since December 2024.

What changed and the deadlines that are left

R-410A is the refrigerant most U.S. home air conditioners and heat pumps have used for years. Under a federal law called the American Innovation and Manufacturing (AIM) Act, the EPA limits how much of these refrigerants (called HFCs) can be made or imported, and limits which ones new equipment can use. The measure it uses is global warming potential, or GWP. For home and light commercial AC and heat pumps, the limit is 700. R-410A is above it, so manufacturers moved to new refrigerants such as R-454B.

The EPA’s 2023 rule stopped the manufacture and import of these R-410A systems on January 1, 2025. A later rule gave contractors until January 1, 2026 to install older stock. Then, on May 21, 2026, the EPA finalized a rule removing that install deadline. It took effect July 27, 2026. The EPA said the change lets “tens, if not hundreds, of thousands” of systems built before 2025 still be installed (EPA fact sheet).

EquipmentMaking or importing new equipmentInstalling itStatus (Nov. 17, 2026)
Home and light commercial split systems and mini-splits (new installs)No new equipment above the 700 limit (this includes R-410A) made or imported since Jan. 1, 2025No deadline, as long as every specified part was made or imported before Jan. 1, 2025Still allowed until old stock runs out
Replacing parts on an existing R-410A home systemRepair parts are not restrictedRepairs are allowed. Replacing the outdoor condensing unit alone counts as a repairAllowed
Variable refrigerant flow (VRF) systemsNo new equipment above 700 made or imported since Jan. 1, 2026Must be installed by Jan. 1, 2027 (Jan. 1, 2028 for buildings with an approved permit issued before Oct. 5, 2023 that approved an HFC)Deadline in about 6 weeks
Window and portable AC units (factory-sealed)No new units above 700 made or imported since Jan. 1, 2025Not field-installed. The 2023 rule banned sale of noncompliant factory-sealed products 3 years after the manufacture banOld stock can still be sold for now

Sources: EPA Technology Transitions restrictions by sector, the May 26, 2026 final rule (91 FR 31284) and the EPA fact sheet. The limit applies to the refrigerant’s GWP. In EPA terms, “install” means completing the system’s refrigerant circuit and charging it so it is ready to use.

Repairs, leak rules and refrigerant supply

  • Repairs are allowed. The rules do not restrict parts used to repair existing systems. Replacing the outdoor condensing unit on an existing R-410A system is a repair. If the indoor coil is later replaced too, the EPA counts that as a new system, which must meet the 700 limit.
  • Home AC is outside the leak repair rule. Since January 1, 2026, owners and technicians must find and fix leaks in certain appliances holding 15 pounds or more of HFC refrigerant. Residential and light commercial AC and heat pump systems are not covered (EPA leak repair fact sheet).
  • Reclaimed refrigerant rules. Since January 1, 2026, refrigerant sold as “reclaimed” can contain no more than 15% newly made HFCs. From January 1, 2029, servicing of supermarket systems, refrigerated transport and automatic commercial ice makers must use reclaimed refrigerant (EPA reclamation fact sheet). Home AC is not on that list.
  • Less new refrigerant in 2029. The AIM Act phasedown takes a 70% reduction step in 2029. The EPA says this “will constrain HFC production and import and could result in an overall price increase for HFCs,” and that R-410A prices “may rise as the phasedown continues.” Production and imports continue at 15% of the baseline from 2036 on (Federal Register, May 26, 2026).

How HVAC equipment prices changed

The Bureau of Labor Statistics Producer Price Index tracks what manufacturers get for their products. It is not what you pay a distributor, but it shows the direction. Here is the change to the latest month available.

ProductLatest monthChange since same month 2019Change since Dec. 2024Change in the past year
All AC, refrigeration and warm air heating equipmentOct. 2026+59.8%+9.7%+4.5%
Unitary air conditioners (not heat pumps)Sept. 2026+52.8%+9.1%+6.2%
Heat pumpsOct. 2026+21.1%-1.9%-3.4%
Refrigeration condensing unitsAug. 2026+65.1%+3.9%+1.8%
Parts for AC and heat transfer equipmentOct. 2026+56.6%+8.7%+3.4%
Warm air furnacesOct. 2026+59.7%+13.1%+6.3%

Download the data (CSV)

Two things stand out. Unitary air conditioner prices are up 9.1% since December 2024, the month before the R-410A manufacturing cutoff. Heat pump prices are down 3.4% from a year earlier. The data does not say why prices moved. Tariffs, metal costs, demand and the switch to new refrigerants all play a part. Recent months are preliminary and can be revised.

Examples

  • A homeowner’s R-410A condenser dies in 2027. A contractor can replace just the outdoor unit with an R-410A replacement unit, because that counts as a repair. Replacing both the outdoor unit and the indoor coil means a new system, which must use a compliant refrigerant unless all parts came from pre-2025 stock.
  • A distributor has R-410A split systems built in 2024. Since July 27, 2026, a contractor can install them in new homes or replacements with no deadline, as long as every specified part was made or imported before 2025.
  • A commercial contractor has an R-410A VRF job planned for spring 2027. That job can’t use R-410A VRF equipment unless the building had an approved permit issued before October 5, 2023 that approved an HFC, in which case the deadline is January 1, 2028.

What HVAC contractors should do now

  1. Check the manufacture date on any R-410A equipment before you quote it. Keep the paperwork in the job file.
  2. Finish R-410A VRF installs before January 1, 2027, or confirm the building qualifies for the 2028 date.
  3. Explain the options to customers: a repair on the old system, a pre-2025 R-410A system, or a new-refrigerant system. Point out that R-410A refrigerant may cost more after 2029.
  4. Train for new refrigerants. Many replacement refrigerants, such as R-454B, are mildly flammable (safety class A2L) and need different handling and tools.
  5. Price with current costs. Equipment prices have moved a lot since 2019. Update your quotes and maintenance agreements.

Running an HVAC business?

Installs and repairs carry risk. Compare HVAC business insurance quotes from Simply Business. Starting out? Form your LLC with LegalNature.

We may earn a commission if you use these links. It doesn’t change what you pay, and it doesn’t affect the information on this page.

More for HVAC shops: air conditioner and heat pump shipments, heat pump rebates by state and how to price an HVAC maintenance agreement.

How we checked this

We read the EPA’s HFC restrictions by sector page, the final rule published May 26, 2026 (effective July 27, 2026), the EPA fact sheets on the rule, leak repair and reclamation, and pulled Producer Price Index data from the Bureau of Labor Statistics on November 17, 2026 (series PCU333415333415, PCU333415333415E, PCU333415333415H, PCU3334153334155, PCU333415333415D, PCU333415333415C). This page is general information, not legal advice. Check the rule text for your exact equipment.

Common questions

Can you still install R-410A in 2027?

Yes, for most home and light commercial systems. In a final rule effective July 27, 2026, the EPA removed the installation deadline for residential and light commercial AC and heat pump systems if all specified parts were made or imported before January 1, 2025. Those can be installed until the stock runs out. VRF systems are different: they must be installed by January 1, 2027.

Can I still buy new R-410A equipment made in 2026?

No. Since January 1, 2025, new home and light commercial AC and heat pump systems made in or imported into the U.S. must use a refrigerant with a global warming potential of 700 or less. R-410A is above that limit. The only new R-410A systems you can install are from stock made or imported before 2025.

Can I repair an existing R-410A system?

Yes. The rules do not restrict parts used to repair existing systems. Replacing just the outdoor condensing unit counts as a repair. But if you later also replace the indoor coil, the EPA treats that as installing a new system, which must use a refrigerant under the limit.

Will R-410A refrigerant get more expensive?

It may. The EPA says the 2029 step of the HFC phasedown will cut production and imports, and that the price of older refrigerants like R-410A “may rise as the phasedown continues.” Production and imports continue at 15% of the baseline from 2036 on, so refrigerant for repairs will still exist.

Do leak repair rules apply to home AC systems?

No. The EPA leak repair rules that started January 1, 2026 cover certain appliances holding 15 pounds or more of HFC refrigerant, but residential and light commercial AC and heat pump systems are not covered.

Published November 17, 2026. We will update this page if the EPA changes the rules again.